Fire Resistance Tests of Floor Truss Systems (Draft)
Download

Thank you for downloading Fire Resistance Tests of Floor Truss Systems (Draft)

If your download does not start automatically after a few seconds, please click on the Download link above

Description:

 

The National Institute of Standards and Technology (NIST) review of available documents related to the design and construction of the World Trade Center (WTC) towers indicated that the fire performance of the composite floor system of the WTC towers was an issue of concern to the building owners and designers from the original design and throughout the service life of the buildings. However, no fire resistance tests of the WTC floor system were ever conducted.  As a result, NIST conducted a series of four standard fire resistance tests (ASTM E 119). In this series of tests, the effects of three factors were studied: (1) fireproofing thickness, (2) test restraint conditions, and (3) scale of the test. The tests were conducted by Underwriters Laboratories, Inc. and represented both full-scale (35 ft span), and reduced scale (17 ft span) floor assemblies constructed to represent the original design as closely as practical. For three of the tests, the thickness of the sprayed fire resistive material was ¾ in. which represented the average thickness applied in the original construction. In the fourth test, the thickness of applied fireproofing was ½ in. which was the thickness specified for the original design.  Tests were conducted in both the restrained and unrestrained condition to provide bounds on the expected performance of the floor system under the standard fire exposure. The restrained full-scale WTC floor system obtained a fire resistance rating of 1½ h while the unrestrained floor system achieved a 2 h rating. For the unrestrained test condition, specimens protected with ¾ in. thick sprayed fire resistive material were able to sustain the maximum design load for approximately 2 h without collapsing; in the unrestrained test, the load was maintained without collapsing for 3½ h. Past experience with the ASTM E 119 test method would lead investigators to expect that the unrestrained floor assembly would not perform as well as the restrained assembly, and therefore, would receive a lower fire rating. A fire rating of 2 h was determined from the reduced-scale test with the average applied fireproofing thickness of ¾ in. while a fire rating of 1½ h was determined from the full-scale test with the same fireproofing thickness.  This finding raises the question of whether or not a fire rating based on the ASTM E 119 performance of a 17 ft span floor assembly is scalable to a larger floor system such as found in the WTC towers where spans ranged from 35 ft to 60 ft.

File Size:
6.0 MB
Downloads:
22
File Author:
John Gross, Frederick Hervey, Mark Izydorek, John Mammoser, and Joseph Treadway
Submitted On:
05 Dec 2006
İstanbul nakliyat dtunnel ktunnel